  • Code: 11-2T01, 11-2T11, 11-2T21
  • Description:Load tray with [Letter], [Plain] paper
    Load tray 1 with [Letter], [Plain] paper
    Load tray 2 with [Letter], [Plain] paper
    Load tray 3 with [Letter], [Plain] paper
    Load tray 4 with [Letter], [Plain] paper
    Load MP with [Letter], [Plain] paper
  • Causes:Paper in tray is not matched to the machine paper setting.
  • Remedy:1) Check and change the paper setting of the corresponding tray properly.
  • Code: 11-2T31, 11-2T41, 11-2T61
  • Description:Load tray with [Letter], [Plain] paper
    Load tray 1 with [Letter], [Plain] paper
    Load tray 2 with [Letter], [Plain] paper
    Load tray 3 with [Letter], [Plain] paper
    Load tray 4 with [Letter], [Plain] paper
    Load MP with [Letter], [Plain] paper
  • Causes:Paper in tray is not matched to the machine paper setting.
  • Remedy:1) Check and change the paper setting of the corresponding tray properly.
  • Code: 61-1111
  • Description:Booting Failure: #61-1111. Turn off then on. Call for service if the problem persists
  • Causes:Hibernation image creation is failed.
  • Remedy:1) Turn the machine on with a normal booting.
    2) Enter the SVC mode. Select “Hibernation On” again.
  • Code: A1-1111, A1-1113
  • Description:Motor Failure: #A1-1111. Turn off then on. Call for service if the problem persists.
    Motor Failure: #A1-1113. Turn off then on. Call for service if the problem persists.
  • Causes:Regi/MP motor operation is abnormal.
    • A1–1111 : Regi/MP motor is stopped but machine recognizes it as operational.
    • A1–1113 : Regi/MP motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around Regi./MP unit.
    3) Remove the rear cover.
    4) Check if the Regi/MP motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0000) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor(JC31-00123B). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100C (220V) / JC44-00093C (110V)). - If the control signal is abnormal, replace the main board(JC92-02742A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.
  • Code: A1-1211, A1-1213

  • Description:Motor Failure: #A1-1211. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-1213. Turn off then on. Call for service if the problem persists
  • Causes:Fuser motor operation is abnormal.
    • A1–1211 : Fuser motor is stopped but machine recognizes it as operational.
    • A1–1213 : Fuser motor is operating but recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around fuser unit.
    3) Remove the rear cover.
    4) Check if the fuser motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0120) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor(JC31-00123B). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100C (220V) / JC44-00093C (110V)). - If the control signal is abnormal, replace the main board(JC92-02742A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.
  • Code: A1-1611, A1-1612, A1-1613
  • Description:Motor Failure: #A1-1611. Turn off then on. Call for service if the problem persists.
    Motor Failure: #A1-1612. Turn off then on. Call for service if the problem persists.
    Motor Failure: #A1-1613. Turn off then on. Call for service if the problem persists.
  • Causes:ITB motor operation is abnormal
    • A1–1611 : ITB motor is stopped but machine recognizes it as operational.
    • A1–1612 : ITB motor is not operated for print-job.
    • A1–1613 : ITB motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Remove the ITB unit
    4) Check if the ITB motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0450) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor(JC31-00123B). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100C (220V) / JC44-00093C (110V)). - If the control signal is abnormal, replace the main board(JC92-02742A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.
  • Code: A1-2211, A1-2212, A1-2213
  • Description:Motor Failure: #A1-2211. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-2212. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-2213. Turn off then on. Call for service if the problem persists
  • Causes:Yellow OPC motor operation is abnormal.
    • A1–2211 : Yellow OPC motor is stopped but machine recognizes it as operational.
    • A1–2212 : Yellow OPC motor is not operated for print-job.
    • A1–2213 : Yellow OPC motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around yellow drum drive unit.
    3) Remove the rear cover.
    4) Check if the yellow OPC motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select the yellow OPC motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0041) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor(JC31-00123B). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100C (220V) / JC44-00093C (110V)). - If the control signal is abnormal, replace the main board(JC92-02742A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.
  • Code: A1-2311, A1-2312, A1-2313
  • Description:Motor Failure: #A1-2311. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-2312. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-2313. Turn off then on. Call for service if the problem persists
  • Causes:Magenta OPC motor operation is abnormal.
    • A1–2311 : Magenta OPC motor is stopped but machine recognizes it as operational.
    • A1–2312 : Magenta OPC motor is not operated for print-job.
    • A1–2313 : Magenta OPC motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around magenta drum drive unit.
    3) Remove the rear cover.
    4) Check if the magenta OPC motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select the magenta OPC motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0042) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor(JC31-00123B). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100C (220V) / JC44-00093C (110V)). - If the control signal is abnormal, replace the main board(JC92-02742A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.
  • Code: A1-2411, A1-2412, A1-2413
  • Description:Motor Failure: #A1-2411. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-2412. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-2413. Turn off then on. Call for service if the problem persists
  • Causes:Cyan OPC motor operation is abnormal.
    • A1–2411 : Cyan OPC motor is stopped but machine recognizes it as operational.
    • A1–2412 : Cyan OPC motor is not operated for print-job.
    • A1–2413 : Cyan OPC motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around cyan drum drive unit.
    3) Remove the rear cover.
    4) Check if the cyan OPC motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select the cyan OPC motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0043) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor(JC31-00123B). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100C (220V) / JC44-00093C (110V)). - If the control signal is abnormal, replace the main board(JC92-02742A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.
  • Code: A1-2511, A1-2512, A1-2513
  • Description:Motor Failure: #A1-2511. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-2512. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-2513. Turn off then on. Call for service if the problem persists
  • Causes:Black OPC motor operation is abnormal.
    • A1–2511 : Black OPC motor is stopped but machine recognizes it as operational.
    • A1–2512 : Black OPC motor is not operated for print-job.
    • A1–2513 : Black OPC motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around black drum drive unit.
    3) Remove the rear cover.
    4) Check if the black OPC motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select the black OPC motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0044) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor(JC31-00123B). • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board (JC44-00100C (220V) / JC44-00093C (110V)). - If the control signal is abnormal, replace the main board(JC92-02742A). b) If the motor is operational, • Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace the harness.
  • Code: A1-4310
  • Description:Motor Failure: #A1-4310. Turn off then on. Call for service if the problem persists
  • Causes:The T1 engage motor operation is abnormal.
  • Remedy:1) Enter SVC mode. Select the T1 engage motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0080) Push the start button and check the motor operation.
    2) If the motor is not operational, a) Open the side cover. Check if the ITB connector is connected correctly or is deformed. b) If the harness is defective, replace it. c) Remove the ITB unit from the machine. Check if the photo interrupter sensor is contaminated or assembled properly. d) If the photo sensor is defective, replace it. e) If the motor is operational but the engage gear is not operational, replace the main drive unit(JC93-00723A).
    3) If there is a motor noise or the motor is not operational normally, check the following : a) Remove the rear cover. Check if the T1 engage motor in the main drive unit is defective. i) Rotate the motor manually. • If the motor operation is stiff, replace the motor(JC93-00452A). ii) Measure the resistance value with DVM. • If the measured value is out of the standard area (7~10 ohm), replace the motor(JC93-00452A). b) If the motor is normal, measure the motor signal with DVM. • If the phase output voltage is changed in 0~24V(8~10V), the output value is normal. • If the phase output voltage is not changed to 0 or 24V, replace the main board(JC92-02742A).
  • Code: A1-5212, A1-5213
  • Description:Motor Failure: #A1-5212. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-5213. Turn off then on. Call for service if the problem persists
  • Causes:Yellow toner is not supplied normally.
    • A1–5212 : Toner supply is stopped during operation.
    • A1–5213 : Toner is not supplied.
  • Remedy:1) Open the front cover. If the yellow toner pipe is blocked, open it.
    2) Turn the machine off then on. If the error persists, check the following steps.
    3) Enter SVC mode. Select the yellow toner supply motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 111-0000 : Toner Dispense Motor Yellow
    4) If the motor is not operational, measure the yellow motor power with DVM. a) If 24V power is generated, replace the yellow toner supply motor(JC93-00446A). b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100C (220V) / JC44-00093C (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92-02742A).
  • Code: A1-5312, A1-5313

  • Description:Motor Failure: #A1-5312. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-5313. Turn off then on. Call for service if the problem persists
  • Causes:Magenta toner is not supplied normally.
    • A1–5312 : Toner supply is stopped during operation.
    • A1–5313 : Toner is not supplied.
  • Remedy:1) Open the front cover. If the magenta toner pipe is blocked, open it.
    2) Turn the machine off then on. If the error persists, check the following steps.
    4) If the motor is not operational, measure the magenta motor power with DVM. a) If 24V power is generated, replace the magenta toner supply motor(JC93-00446A). b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100C (220V) / JC44-00093C (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92-02742A).
  • Code: A1-5412, A1-5413
  • Description:Motor Failure: #A1-5412. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-5413. Turn off then on. Call for service if the problem persists
  • Causes:Cyan toner is not supplied normally.
    • A1–5412 : Toner supply is stopped during operation.
    • A1–5413 : Toner is not supplied.
  • Remedy:1) Open the front cover. If the cyan toner pipe is blocked, open it.
    2) Turn the machine off then on. If the error persists, check the following steps.
    3) Enter SVC mode. Select the cyan toner supply motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 111-0020 : Toner Dispense Motor Cyan
    4) If the motor is not operational, measure the cyan motor power with DVM. a) If 24V power is generated, replace the cyan toner supply motor(JC93-00446A). b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100C (220V) / JC44-00093C (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92-02742A).
  • Code: A1-5512, A1-5513
  • Description:Motor Failure: #A1-5512. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-5513. Turn off then on. Call for service if the problem persists
  • Causes:Black toner is not supplied normally.
    • A1–5212 : Toner supply is stopped during operation.
    • A1–5213 : Toner is not supplied.
  • Remedy:1) Open the front cover. If the black toner pipe is blocked, open it.
    2) Turn the machine off then on. If the error persists, check the following steps.
    3) Enter SVC mode. Select the black toner supply motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 111-0030 : Toner Dispense Motor Black
    4) If the motor is not operational, measure the black motor power with DVM. a) If 24V power is generated, replace the black toner supply motor(JC93-00446A). b) If 24V power is not generated, Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100C (220V) / JC44-00093C (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92-02742A).
  • Code: A2-1211, A2-1212
  • Description:Fan Failure: #A2–1211 / A2–1212 / A2–1221 / A2–1223. Turn off then on. Call for service if the problem persists
  • Causes:SMPS or Fuser or Duplex or LSU fan is not operational.
    • SMPS fan error : A2–1211 / A2–1212 / A2–1221 / A2–1223
    • Duplex fan error : A2–1521 / A2–1523
    • Fuser fan error : A2–2310 / A2–2311 / A2–2321 / A2–2323
  • Remedy:1) Turn the machine off.
    2) Remove the rear cover.
    3) Check if the corresponding fan connector is connected correctly.
    4) If the connection is OK, Enter SVC mode and execute fan test. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 100-0260 : SMPS Fan Run • 109-0040 : Fuser Fan Run
    5) If the fan is not operational, measure the fan power. (Red line) a) If 24V power is generated, replace the defective fan. • Fuser Fan : JC31–00161A • SMPS Fan : JC31–00160B b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100C (220V) / JC44-00093C (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92–02742A).
    6) If the fan operation is normal but the error persists, a) Check the yellow line signal with DVM. (Refer to the image in step 5) b) Check fan operation as connected or disconnected. • If the Lock signal is 0V continually, check the harness. If the harness is OK, replace the main board. • If the signal value is different from the table above, replace the fan.
  • Code: A2-1221, A2-1223
  • Description:Fan Failure: #A2–1211 / A2–1212 / A2–1221 / A2–1223. Turn off then on. Call for service if the problem persists
  • Causes:SMPS or Fuser or Duplex or LSU fan is not operational.
    • SMPS fan error : A2–1211 / A2–1212 / A2–1221 / A2–1223
    • Duplex fan error : A2–1521 / A2–1523
    • Fuser fan error : A2–2310 / A2–2311 / A2–2321 / A2–2323
  • 5) If the fan is not operational, measure the fan power. (Red line) a) If 24V power is generated, replace the defective fan. • Fuser Fan : JC31–00161A • SMPS Fan : JC31–00160B b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100C (220V) / JC44-00093C (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92–02742A).
    6) If the fan operation is normal but the error persists, a) Check the yellow line signal with DVM. (Refer to the image in step 5) b) Check fan operation as connected or disconnected. • If the Lock signal is 0V continually, check the harness. If the harness is OK, replace the main board. • If the signal value is different from the table above, replace the fan.
  • Code: A2-1521, A2-1523
  • Description:Fan Failure: #A2–1521 / A2–1523. Turn off then on. Call for service if the problem persists
  • Causes:SMPS or Fuser or Duplex or LSU fan is not operational.
    • SMPS fan error : A2–1211 / A2–1212 / A2–1221 / A2–1223
    • Duplex fan error : A2–1521 / A2–1523
    • Fuser fan error : A2–2310 / A2–2311 / A2–2321 / A2–2323
  • 5) If the fan is not operational, measure the fan power. (Red line) a) If 24V power is generated, replace the defective fan. • Fuser Fan : JC31–00161A • SMPS Fan : JC31–00160B b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100C (220V) / JC44-00093C (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92–02742A).
    6) If the fan operation is normal but the error persists, a) Check the yellow line signal with DVM. (Refer to the image in step 5) b) Check fan operation as connected or disconnected. • If the Lock signal is 0V continually, check the harness. If the harness is OK, replace the main board. • If the signal value is different from the table above, replace the fan.
  • Code: A2-2310, A2-2311
  • Description:Fan Failure: #A2–2310 / A2–2311 / A2–2321 / A2–2323. Turn off then on. Call for service if the problem persists
  • Causes:SMPS or Fuser or Duplex or LSU fan is not operational.
    • SMPS fan error : A2–1211 / A2–1212 / A2–1221 / A2–1223
    • Duplex fan error : A2–1521 / A2–1523
    • Fuser fan error : A2–2310 / A2–2311 / A2–2321 / A2–2323
  • Remedy:1) Turn the machine off.
    2) Remove the rear cover.
    3) Check if the corresponding fan connector is connected correctly.
    4) If the connection is OK, Enter SVC mode and execute fan test. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 100-0260 : SMPS Fan Run • 109-0040 : Fuser Fan Run
    5) If the fan is not operational, measure the fan power. (Red line) a) If 24V power is generated, replace the defective fan. • Fuser Fan : JC31–00161A • SMPS Fan : JC31–00160B b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100C (220V) / JC44-00093C (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92–02742A).
    6) If the fan operation is normal but the error persists, a) Check the yellow line signal with DVM. (Refer to the image in step 5) b) Check fan operation as connected or disconnected. • If the Lock signal is 0V continually, check the harness. If the harness is OK, replace the main board. • If the signal value is different from the table above, replace the fan.
  • Code: A2-2321, A2-2323
  • Description:Fan Failure: #A2–2310 / A2–2311 / A2–2321 / A2–2323. Turn off then on. Call for service if the problem persists
  • Causes:SMPS or Fuser or Duplex or LSU fan is not operational.
    • SMPS fan error : A2–1211 / A2–1212 / A2–1221 / A2–1223
    • Duplex fan error : A2–1521 / A2–1523
    • Fuser fan error : A2–2310 / A2–2311 / A2–2321 / A2–2323
  • Remedy:1) Turn the machine off.
    2) Remove the rear cover.
    3) Check if the corresponding fan connector is connected correctly.
    4) If the connection is OK, Enter SVC mode and execute fan test. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 100-0260 : SMPS Fan Run • 109-0040 : Fuser Fan Run
    5) If the fan is not operational, measure the fan power. (Red line) a) If 24V power is generated, replace the defective fan. • Fuser Fan : JC31–00161A • SMPS Fan : JC31–00160B b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00100C (220V) / JC44-00093C (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92–02742A).
    6) If the fan operation is normal but the error persists, a) Check the yellow line signal with DVM. (Refer to the image in step 5) b) Check fan operation as connected or disconnected. • If the Lock signal is 0V continually, check the harness. If the harness is OK, replace the main board. • If the signal value is different from the table above, replace the fan.
  • Code: A3-2113, A3-4114

  • Description:The CTD/ACR sensor is dirty. Please clean it with soft cloth or paper.
  • Causes:CTD/ACR sensor window is contaminated.
  • Remedy:1) Open the side cover.
    2) Clean the sensor window [A] with a soft cloth.
    3) Close the side cover.
    4) Enter SVC mode. Select the “CTD Sensor Cleaning” (Diagnostics Image Management > Auto Color Tone Adjustment Condition > CTD Sensor Cleaning)
    5) When pop up appears, select the “Yes” button.
    NOTE a) CTD sensor calibration will start. Then “CTD sensor failure” error will be solved b) If you don’t execute the CTD sensor cleaning in SVC mode, error message persists.
  • Code: A3-3111, A3-3112
  • Description:Sensor Failure: #A3-3111. Turn off then on. Call for service if the problem persists
    Sensor Failure: #A3-3112. Turn off then on. Call for service if the problem persists
  • Causes:The NC sensor in the fuser unit is defective. / The sensor signal is abnormal due to a defective harness.
    • A3–3111 : Center NC sensor is in short status.
    • A3–3112 : Center NC sensor is in open status.
    • A3–3113 : Side NC sensor is in short status.
    • A3–3114 : Side NC sensor is in open status.
  • Remedy:1) Enter SVC mode. Execute sensor test to check the sensor operation. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 109-0000 : Fuser Temperature A • 109-0010 : Fuser Temperature B
    3) Measure the resistance value of the thermistor (1404-001453). If the measured value is out of 307KΩ~430KΩ @25℃, replace the thermistor.
    4) Install the fuser unit after replacing the thermistor.
    5) If the error persists, replace the fuser unit (JC91-01157A(220V) / JC91–01158A (110V)).
    6) If the error persists after replacing fuser unit, replace the main board(JC92–02742A).
  • Code: A3-3113, A3-3114
  • Description:Sensor Failure: #A3-3113. Turn off then on. Call for service if the problem persists
    Sensor Failure: #A3-3114. Turn off then on. Call for service if the problem persists
  • Causes:The NC sensor in the fuser unit is defective. / The sensor signal is abnormal due to a defective harness.
    • A3–3111 : Center NC sensor is in short status.
    • A3–3112 : Center NC sensor is in open status.
    • A3–3113 : Side NC sensor is in short status.
    • A3–3114 : Side NC sensor is in open status.
  • Remedy:1) Enter SVC mode. Execute sensor test to check the sensor operation. (Diagnostics > Engine Diagnostics > Engine Test Routines) • 109-0000 : Fuser Temperature A • 109-0010 : Fuser Temperature B
    3) Measure the resistance value of the thermistor (1404-001453). If the measured value is out of 307KΩ~430KΩ @25℃, replace the thermistor.
    4) Install the fuser unit after replacing the thermistor.
    5) If the error persists, replace the fuser unit (JC91-01157A(220V) / JC91–01158A (110V)).
    6) If the error persists after replacing fuser unit, replace the main board(JC92–02742A).
  • Code: A3-3210, A3-3211, A3-3212
  • Description:Sensor Failure: #A3-3210. Turn off then on. Call for service if the problem persists
    Sensor Failure: #A3-3211. Turn off then on. Call for service if the problem persists
    Sensor Failure: #A3-3212. Turn off then on. Call for service if the problem persists
  • Causes:Inner temperature sensor is defective.
    • A3–3210 : Inner temperature sensor value is abnormal.
    • A3–3211 : Inner temperature sensor is in short status.
    • A3–3212 : Inner temperature sensor is in open status.
  • Remedy:1) Open the side cover. Check the connection. • If the connection is OK, replace the photo sensor (1404-001417).
    2) If the sensor is normal, replace the main board(JC92-02742A).