Samsung MultiXpress X3220NR код ошибки
20.12.2019 25 0.0 0
  • Code: 11-2T11, 11-2T21, 11-2T31
  • Description:Tray 1 paper mismatch
    Tray 2 paper mismatch
    Tray 3 paper mismatch
    Tray 4 paper mismatch
    MP tray paper mismatch
  • Causes:Paper in tray is not matched to the machine paper setting.
  • Remedy:1) Check and change the paper setting of the corresponding tray properly.
  • Code: 11-2T41, 11-2T61
  • Description:Tray 1 paper mismatch
    Tray 2 paper mismatch
    Tray 3 paper mismatch
    Tray 4 paper mismatch
    MP tray paper mismatch
  • Causes:Paper in tray is not matched to the machine paper setting.
  • Remedy:1) Check and change the paper setting of the corresponding tray properly.
  • Code: A1-1111, A1-1113
  • Description:Main Motor Failure: #A1-1111. Turn off then on. Call for service if the problem persists
    Main Motor Failure: #A1-1113. Turn off then on. Call for service if the problem persists
  • Causes:Regi/MP motor operation is abnormal.
    • A1–1111 : Regi/MP motor is stopped but machine recognizes it as operational.
    • A1–1113 : Regi/MP motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around Regi./MP unit.
    3) Remove the rear cover.
    4) Check if the Regi/MP motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor. • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board . - If the control signal is abnormal, replace the main board. b) If the motor is operational, replace the main board.
  • Code: A1-1211, A1-1213
  • Description:Fuser Motor Failure: #A1-1211. Turn off then on. Call for service if the problem persists
    Fuser Motor Failure: #A1-1213. Turn off then on. Call for service if the problem persists
  • Causes:Fuser motor operation is abnormal.
    • A1–1211 : Fuser motor is stopped but machine recognizes it as operational.
    • A1–1213 : Fuser motor is operating but recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around fuser unit.
    3) Remove the rear cover.
    4) Check if the fuser motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor. • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board. - If the control signal is abnormal, replace the main board. b) If the motor is operational, replace the main board.
  • Code: A1-1611, A1-1612, A1-1613

  • Description:ITB Motor Failure: #A1-1611. Turn off then on. Call for service if the problem persists
    ITB Motor Failure: #A1-1612. Turn off then on. Call for service if the problem persists
    ITB Motor Failure: #A1-1613. Turn off then on. Call for service if the problem persists
  • Causes:ITB motor operation is abnormal
    • A1–1611 : ITB motor is stopped but machine recognizes it as operational.
    • A1–1612 : ITB motor is not operated for print-job.
    • A1–1613 : ITB motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Remove the ITB unit
    3) Remove the rear cover.
    4) Check if the ITB motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor. • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board. - If the control signal is abnormal, replace the main board. b) If the motor is operational, replace the main board.
  • Code: A1-2211, A1-2212, A1-2213
  • Description:OPC Motor Failure: #A1-2211. Turn off then on. Call for service if the problem persists
    OPC Motor Failure: #A1-2212. Turn off then on. Call for service if the problem persists
    OPC Motor Failure: #A1-2213. Turn off then on. Call for service if the problem persists
  • Causes:Yellow OPC motor operation is abnormal.
    • A1–2211 : Yellow OPC motor is stopped but machine recognizes it as operational.
    • A1–2212 : Yellow OPC motor is not operated for print-job.
    • A1–2213 : Yellow OPC motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around yellow drum drive unit.
    3) Remove the rear cover.
    4) Check if the yellow OPC motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select the yellow OPC motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor. • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board. - If the control signal is abnormal, replace the main board. b) If the motor is operational, replace the main board.
  • Code: A1-2311, A1-2312, A1-2313
  • Description:Motor Failure: #A1-2311. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-2312. Turn off then on. Call for service if the problem persists
    Motor Failure: #A1-2313. Turn off then on. Call for service if the problem persists
  • Causes:Magenta OPC motor operation is abnormal.
    • A1–2311 : Magenta OPC motor is stopped but machine recognizes it as operational.
    • A1–2312 : Magenta OPC motor is not operated for print-job.
    • A1–2313 : Magenta OPC motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around magenta drum drive unit.
    3) Remove the rear cover.
    4) Check if the magenta OPC motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select the magenta OPC motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor. • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board. - If the control signal is abnormal, replace the main board. b) If the motor is operational, replace the main board.
  • Code: A1-2411, A1-2412, A1-2413
  • Description:OPC Motor Failure: #A1-2411. Turn off then on. Call for service if the problem persists
    OPC Motor Failure: #A1-2412. Turn off then on. Call for service if the problem persists
    OPC Motor Failure: #A1-2413. Turn off then on. Call for service if the problem persists
  • Causes:Cyan OPC motor operation is abnormal.
    • A1–2411 : Cyan OPC motor is stopped but machine recognizes it as operational.
    • A1–2412 : Cyan OPC motor is not operated for print-job.
    • A1–2413 : Cyan OPC motor is operating but machine recognizes status as "Stopped".
  • Remedy:1) Turn the machine off then on. If the error persists, turn the machine off again.
    2) Open the side cover. Check if there are any foreign substances or paper around cyan drum drive unit.
    3) Remove the rear cover.
    4) Check if the cyan OPC motor connector is connected correctly.
    5) If the connection is OK, turn the machine on. Enter SVC mode. Select the cyan OPC motor test. (Diagnostics > Engine Diagnostics > Engine Test Routines) Check the motor operation. a) If the motor is not operational, • Check the signal and power with the DVM. • If the checked result is normal, replace the motor. • If the checked result is abnormal, check the following. - If 24V power is not generated, replace the SMPS board. - If the control signal is abnormal, replace the main board. b) If the motor is operational, replace the main board.

Теги:Samsung MultiXpress X3220NR код оши, Samsung MultiXpress X3220NR error c