02.12.2019 11 0.0 0
  • Code: 0201
  • Display:Print Unable 02 Turn the power off and then back on again.
  • Description:The speed of the main motor does not stabilize within the specified time.
  • Remedy:1 Connection failure of the main motor harness Reconnect the main motor harness. 2 Connection failure of the motor encoder PCB flat cable Reconnect the motor encoder PCB flat cable. 3 Low voltage power supply PCB failure Replace the low voltage power supply PCB unit. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 0300
  • Display:Print Unable 03 Turn the power off and then back on again.
  • Description:Cannot detect the lock signal of the polygon motor for the laser unit (second time).
  • Remedy:1 Connection failure of the laser unit flat cable Reconnect the laser unit flat cable. 2 Laser unit flat cable failure Replace the laser unit flat cable. 3 Laser unit failure Replace the laser unit. 4 Low voltage power supply PCB failure Replace the low voltage power supply PCB unit. 5 Main PCB failure Replace the main PCB ASSY.
  • Code: 0401
  • Display:Print Unable 04 Turn the power off and then back on again.
  • Description:Cannot detect the synchronized signal of the polygon motor for the laser unit.
  • Remedy:1 Connection failure of the polygon motor harness Reconnect the polygon motor harness. 2 Polygon motor failure Replace the laser unit. 3 Low voltage power supply PCB failure Replace the low voltage power supply PCB unit. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 0501
  • Display:Print Unable 05 Turn the power off and then back on again.
  • Description:The center thermistor of the fuser unit has not reached the specified temperature within the specified time.
  • Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error has reset.
    1 Connection failure of the center thermistor harness of the fuser unit Reconnect the center thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the low voltage PCB harness Reconnect the low voltage PCB harness. 4 Fuser unit failure Replace the fuser unit. 5 Low voltage power supply PCB failure Replace the low voltage power supply PCB unit. 6 Main PCB failure Replace the main PCB ASSY.

Code: 0502

  • Display:Print Unable 05 Turn the power off and then back on again.
  • Description:The center thermistor has not reached the specified temperature within the specified time after the fuser unit has reached to a certain temperature.
  • Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error has reset.
    1 Connection failure of the center thermistor harness of the fuser unit Reconnect the center thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the low voltage PCB harness Reconnect the low voltage PCB harness. 4 Fuser unit failure Replace the fuser unit. 5 Low voltage power supply PCB failure Replace the low voltage power supply PCB unit. 6 Main PCB failure Replace the main PCB ASSY.
  • Code: 0503
  • Display:Print Unable 05 Turn the power off and then back on again.
  • Description:The center thermistor of the fuser unit detected a temperature higher than the specified value.
  • Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error has reset.
    1 Connection failure of the center thermistor harness of the fuser unit Reconnect the center thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the low voltage PCB harness Reconnect the low voltage PCB harness. 4 Fuser unit failure Replace the fuser unit. 5 Low voltage power supply PCB failure Replace the low voltage power supply PCB unit. 6 Main PCB failure Replace the main PCB ASSY.
  • Code: 0504
  • Display:Print Unable 05 Turn the power off and then back on again.
  • Description:After the heat unit was heated normally, the center thermistor of the fuser unit detected a temperature lower than the specified value.
  • Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error has reset.
    1 Connection failure of the center thermistor harness of the fuser unit Reconnect the center thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the low voltage PCB harness Reconnect the low voltage PCB harness. 4 Fuser unit failure Replace the fuser unit. 5 Low voltage power supply PCB failure Replace the low voltage power supply PCB unit. 6 Main PCB failure Replace the main PCB ASSY.
  • Code: 0505
  • Display:Print Unable 05 Turn the power off and then back on again.
  • Description:The center thermistor of the fuser unit detected a temperature rise greater than the specified value within the specified time.
  • Remedy:<User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error has reset.
    1 Connection failure of the center thermistor harness of the fuser unit Reconnect the center thermistor harness of the fuser unit. 2 Connection failure of the heater harness of the fuser unit Reconnect the heater harness of the fuser unit. 3 Connection failure of the low voltage PCB harness Reconnect the low voltage PCB harness. 4 Fuser unit failure Replace the fuser unit. 5 Low voltage power supply PCB failure Replace the low voltage power supply PCB unit. 6 Main PCB failure Replace the main PCB ASSY.